Proline Prowirl F 200
Vortex flowmeter

Picture of Vortex flowmeter Proline Prowirl F 200 / 7F2C for utilities ©Endress+Hauser

Proline Prowirl F 200 for utilities

Picture of Vortex flowmeter Prowirl F 200 with mounted pressure measuring unit for gases and liquids ©Endress+Hauser

Prowirl F 200 with mounted pressure measuring unit for gases and liquids (can be rotated through 360 °)

Unboxing and commissioning of Proline Prowirl 200 vortex flowmeter with integrated temperature and pressure measurement

Picture of Vortex flowmeter Prowirl F 200 with mounted pressure measuring unit for steam ©Endress+Hauser

Prowirl F 200 with mounted pressure measuring unit for steam (can be rotated through 360 °)

The Vortex Flow Measuring Principle

Steam Quality Measurement with Prowirl F 200 - For Maximum Operational Safety, Energy and Cost Efficiency

HistoROM data storage concept

This film shows that Prowirl 200 is the most robust vortex flowmeter worldwide even under extreme process conditions.

Detection of wet steam Measurement of the dryness fraction of steam.

Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy

Prowirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology ensures process safety at all times.

  • Benefits

    • Easy energy management – integrated temperature and pressure measurement for steam and gases

    • Space-saving engineering – inlet run compensation

    • Same accuracy down to Re 10 000 – most linear Vortex meter body

    • Long-term stability – robust drift-free...

  • Field of application

    • Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)

    • Suitable for a wide range of applications; optimized for steam applications.

    Device properties

    • Wet steam capabilities for DN 25 to 300 (1 to 12")

    • ...

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • 34
    • Nr 34 Order code 71108602

      I/O module Flow, 2-wr. 2x4-20mA,HART, Ex

      Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: FTM50/FTM51/FTM52. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 34 Order code 71164940

      I/O module, 2-wire, PA/FF, PFS, Ex, V2

      Non-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.

  • 36
    • Order code 71128617

      Overvoltage protection (OVP10),1-Channel

      4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128619

      Overvoltage protection (OVP20),2-Channel

      4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code

      Remote display FHX50 please order with separate order structure.

    • Order code 71197334

      Transmitter electronics FHX50

      Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.

    • Order code 71296840

      Plug M12, VA

      To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.

  • 30
    • Nr 30 Order code XPD0043-

      Electronic, Prowirl 200 Index C

      Main electronic module

  • 34
    • Nr 34 Order code XPD0015-

      I/O module, 2-wire, 4-20mA, HART, Ex

      Non-Ex, Ex. 1x current output HART.

  • 34
    • Nr 34 Order code XPD0016-

      I/O module, 2-wire, 4-20mA,HART, PFS, Ex

      Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.

  • 34
    • Nr 34 Order code XPD0018-

      I/O,2-wire,4-20mA,HART,PFS,4-20mA input

      Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input.

  • 46
  • 47
    • Nr 47 Order code 71377445

      Kit cable harness, PW200, remote,electr.

      Usage: Prowirl 200 Index C, transmitter housing. Integrated pressure-/temp.measurement.

  • 43
    • Nr 43 Order code 71223001

      Kit connection board, remote, electronic

      Usage: Prowirl 200.

  • 44
    • Nr 44 Order code 71223003

      Kit connection board, remote, sensor

      Usage: Prowirl 200.

  • 40
    • Nr 40 Order code XPD0024-

      Display module, SD02, push buttons

      For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.

  • 48
    • Nr 48 Order code 71377446

      Kit connection board, remote, electronic

      Usage: Prowirl 200 Index C, transmitter connection housing. Integrated pressure-/temp.measurement.

  • 40
    • Nr 40 Order code XPD0025-

      Display module, SD03, Touch Control

      For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.

  • 49
    • Nr 49 Order code 71377447

      Kit connection board, remote, sensor

      Usage: Prowirl 200 Index C, sensor connection housing. Integrated pressure-/temp.measurement.

  • 37
    • Nr 37 Order code 71110280

      Terminal set 2-wire, I/O module

      Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 20
    • Nr 20 Order code 71110281

      Cover GT18 316L, HNBR

      Material: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 20 Order code 71110282

      Cover GT18 316L, sight glass, HNBR

      Material: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110291

      Cover GT18 316L, terminal Ex, HNBR

      Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 25 Order code 71110284

      Cover GT18 316L, terminal Ex d, HNBR

      Material: 316L. O-ring EPDM /PTFE coated. Usage: terminal compartment Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 25 Order code 71185516

      Cover GT18 316L, Terminal, OVP, HNBR

      Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57, FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Prowirl 200.

  • 20
    • Nr 20 Order code 71110299

      Cover GT20 Alu, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 20 Order code 71110297

      Cover GT20 Alu, sight glass, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110301

      Cover GT20 Alu, Terminal Ex, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71110302

      Cover GT20 Alu, Terminal Ex d, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71185517

      Cover GT20 Alu, Terminal, OVP, HNBR

      Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 24
    • Nr 24 Order code 71223005

      Kit cover, Alu, remote, sensor

      Usage: Prowirl 200. Consists of: 1x cover Alu, 1x O-Ring 75,87x2,62 NBR coated.

    • Nr 24 Order code 71223006

      Kit cover,Alu,remote,sensor, -50°C/-58°F

      Usage: Prowirl 200. Consists of: 1x cover Alu, 1x O-Ring 75,87x2,62 FVMQ coated.

    • Nr 24 Order code 71223009

      Kit cover, 316L, remote, sensor

      Usage: Prowirl 200. Consists of: 1x cover 316L, 1x O-Ring 75,87x2,62 NBR coated.

    • Nr 24 Order code 71223011

      Kit cover,316L,remote,sensor,-50°C/-58°F

      Usage: Prowirl 200. Consists of: 1x cover 316L, 1x O-Ring 75,87x2,62 FVMQ coated.

  • 65
    • Nr 65 Order code 71110303

      Sealing set GT18/GT19/GT20, EPDM, HNBR

      Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 73
    • Nr 73 Order code 71223053

      Kit gaskets housing, remote, sensor

      Usage: Prowirl 200. Consists of: 1x O-Ring 75,87x2,62 NBR coated for cover. 1x O-Ring 50,39x3,53 HNBR coated for housing/housing support.

    • Nr 73 Order code 71223054

      Kit gaskets housing,remote,sensor, -50°C

      Usage: Prowirl 200, -50°C/-58°F. Consists of: 1x O-Ring 75.87x2.62 FVMQ for cover. 1x O-Ring 50,39x3,53 FVMQ for housing/housing support.

  • 19
    • Nr 19 Order code 71115174

      Housing filter 316L, GT18, 1 set

      Consists of: 2x filter plug metall 316L. 1x pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.

    • Nr 19 Order code 71115175

      Housing filter Brass/Ni GT19/20, 1 set

      Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 17
    • Nr 17 Order code 71115176

      Set housing securing clamps

      Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 61
    • Nr 61 Order code 71223055

      Kit cable, PW200, remote, 5m, bl, M12

      length=5m/15ft with plug M12

    • Nr 61 Order code 71223056

      Kit cable, PW200, remote, 5m, bk, M12

      length=5m/15ft with plug M12

    • Nr 61 Order code 71223057

      Kit cable, PW200, remote, 10m, bl, M12

      length=10m/30ft with plug M12

    • Nr 61 Order code 71223058

      Kit cable, PW200, remote, 10m, bk, M12

      length=10m/30ft with plug M12

    • Nr 61 Order code 71223059

      Kit cable, PW200, remote, 20m, bl, M12

      length=20m/70ft with plug M12

    • Nr 61 Order code 71223060

      Kit cable, PW200, remote, 20m, bk, M12

      length=20m/70ft with plug M12

    • Nr 61 Order code 71223061

      Kit cable, PW200, remote, 30m, bl, M12

      length=30m/90ft with plug M12

    • Nr 61 Order code 71223062

      Kit cable, PW200, remote, 30m, bk, M12

      length=30m/90ft with plug M12

    • Nr 61 Order code 71223063

      Kit cable, PW200, remote, 5m, bl

      length=5m/15ft

    • Nr 61 Order code 71223064

      Kit cable, PW200, remote, 5m, bk

      length=5m/15ft

    • Nr 61 Order code 71223065

      Kit cable, PW200, remote, 10m, bl

      length=10m/30ft

    • Nr 61 Order code 71223067

      Kit cable, PW200, remote, 10m, bk

      length=10m/30ft

    • Nr 61 Order code 71223068

      Kit cable, PW200, remote, 20m, bl

      length=20m/70ft

    • Nr 61 Order code 71223069

      Kit cable, PW200, remote, 20m, bk

      length=20m/70ft

    • Nr 61 Order code 71223070

      Kit cable, PW200, remote, 30m, bl

      length=30m/90ft

    • Nr 61 Order code 71223071

      Kit cable, PW200, remote, 30m, bk

      length=30m/90ft

    • Nr 61 Order code 71223063

      Kit cable, PW200, remote, 5m, bl

      length=5m/15ft

    • Nr 61 Order code 71223064

      Kit cable, PW200, remote, 5m, bk

      length=5m/15ft

    • Nr 61 Order code 71223065

      Kit cable, PW200, remote, 10m, bl

      length=10m/30ft

    • Nr 61 Order code 71223067

      Kit cable, PW200, remote, 10m, bk

      length=10m/30ft

    • Nr 61 Order code 71223068

      Kit cable, PW200, remote, 20m, bl

      length=20m/70ft

    • Nr 61 Order code 71223069

      Kit cable, PW200, remote, 20m, bk

      length=20m/70ft

    • Nr 61 Order code 71223070

      Kit cable, PW200, remote, 30m, bl

      length=30m/90ft

    • Nr 61 Order code 71223071

      Kit cable, PW200, remote, 30m, bk

      length=30m/90ft

    • Nr 61 Order code 71223063

      Kit cable, PW200, remote, 5m, bl

      length=5m/15ft

    • Nr 61 Order code 71223064

      Kit cable, PW200, remote, 5m, bk

      length=5m/15ft

    • Nr 61 Order code 71223065

      Kit cable, PW200, remote, 10m, bl

      length=10m/30ft

    • Nr 61 Order code 71223067

      Kit cable, PW200, remote, 10m, bk

      length=10m/30ft

    • Nr 61 Order code 71223068

      Kit cable, PW200, remote, 20m, bl

      length=20m/70ft

    • Nr 61 Order code 71223069

      Kit cable, PW200, remote, 20m, bk

      length=20m/70ft

    • Nr 61 Order code 71223070

      Kit cable, PW200, remote, 30m, bl

      length=30m/90ft

    • Nr 61 Order code 71223071

      Kit cable, PW200, remote, 30m, bk

      length=30m/90ft

    • Nr 61 Order code 71223073

      Kit cable,PW200, remote,armoured,10m, bk

      length=10m/30ft

    • Nr 61 Order code 71223074

      Kit cable,PW200, remote,armoured,20m, bk

      length=20m/70ft

    • Nr 61 Order code 71223075

      Kit cable,PW200, remote,armoured,30m, bk

      length=30m/90ft

    • Nr 61 Order code 71377465

      Kit cable, PW200 Index C, remote 10m

      Usage: Integrated pressure-/temp.measurement.

    • Nr 61 Order code 71377466

      Kit cable, PW200 Index C, remote 30m

      Usage: Integrated pressure-/temp.measurement.

    • Order code 71162242

      Weather prot. cover GT18/GT19/GT20, 316L

      Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 7X2CXX-

      Transmitter Prowirl 200, 7X2CXX

      For Product: 7F2C, 7D2C, 7R2C, 7O2C.

    • Order code DK7ST-

      Plate conditioner 35 hole, Prowirl

      -200oC...+400oC / -330...+750oF

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

Downloads