T55
Explosion proof TC thermometer, US style

T55
Explosion proof TC thermometer, US style ©Endress+Hauser

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

The high modular thermometer is used for several applications with harsh environments, e.g. in Power Plants, Refineries or in the Chemical or Petrochemical industry. The robust device is designed for use within an existing thermowell. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability.

  • Benefícios

    • FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety

    • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications

    • Remove and install...

  • Campo de aplicação

    The sensor assembly can be used in process industries such as:

    • Chemicals

    • Petrochemical

    • Refineries

    • Offshore Platforms

Características e especificações

Voltar

Details

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    Explosion Proof US style

    modular temperature assembly

    for heavy duty applications

    with extension

    to be used with existing thermowell

  • Terminal head

    TMT162 - aluminium - fieldhousing w. or w/o. display

    TMT162 - SS - fieldhousing w. or w/o. display

    TMT142 - aluminium - fieldhousing w. or w/o. display

    TA30H - aluminum - w. or w/o. display

  • Thermowell / protection tube

    to use with thermowell

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    1/4'' (6,35 mm)

    3/8'' (9,53 mm)

  • Max. immersion length on request

    up to 100" (2540 mm)

    others on request

  • Material protection tube/ thermowell

    Sensor sheath

    316

    Alloy 600

  • Optional coating

    not applicable

  • Process connection

    Thermowell connection

    male thread:

    NPT1/2"

  • Tip shape

    straight

  • Surface roughness Ra

    not applicable

  • Operating temperature range

    Type T:

    -270 °C ...370 °C

    (-454 °F ...698 °F)

    Type J:

    -210 °C ...720 °C

    (-346 °F ...1.328 °F)

    Type E:

    -270 °C ...820 °C

    (-454 °F ...1.508 °F)

    Type K:

    -270 °C ...1.150 °C

    (-454 °F ...2.102 °F)

    Type N:

    -270 °C ...1.150 °C

    (-454 °F ...2.102 °F)

  • Max. process pressure (static)

    not applicable

  • Accuracy

    Standard acc. to ASTM E-230

    Special acc. to ASTM E-230

  • Response time

    63% rt = 1 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    FM XP

    CSA XP

    FM/CSA XP

    CSA GP

  • Certification

    SIL (transmitter only)

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification
  • B
  • A
    • Nr A Order code TU221-

      TC-Insert TU221, Approved, U.S.Style

      Spare part. Thermocouple Insert spring loaded. Flame path Nipple. Thermocouple comply with EMF tables of ASTM E-230 and IEC60584, color codes per ASTM E-230

  • B
    • Nr B Order code TU401-

      Enclosure TU401, U.S.Style

    • Nr B Order code TA30H-

      Terminal Head TA30H

      Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).

    • Order code TMT142E-

      Electronic TMT142E

    • Order code TMT162E-

      Electronic TMT162E

    • Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.