Cerabar T PMP135

Esse produto não está mais disponível.

Verifique a nova geração na seção do predecessor / sucessor ou entre em contato com a Endress+Hauser local.

Características e especificações

Voltar

Details

  • Measuring principle

    Absolute and gauge pressure

  • Characteristic

    Cost-effective pressure transducer with piezoresistive sensor, and flush mounted metallic diaphragm for hygienic applications

  • Supply voltage

    Analogue output:
    12...30V DC,
    Switch output:
    18...32V DC

  • Reference Accuracy

    0,5%

  • Long term stability

    0,15% of URL/year

  • Process temperature

    -25°C...100°C
    (-13°F...212°F)
    135°C for 1h
    (275°F for 1h)

  • Ambient temperature

    -25°C...70°C
    (-13°F...758°F)

  • Measuring cell

    1bar...40bar
    (15psi...600psi)

  • Max. overpressure limit

    160bar (2320psi)

  • Process connection

    Threads
    Tri-Clamp ISO2852
    Hygienic connections

  • Communication

    4...20mA analogue
    PNP switch

  • Certificates / Approvals

    ATEX

  • Safety approvals

    SIL

  • Design approvals

    EN10204-3.1

  • Hygienic approvals

    3A

  • Specialities

    switch output