Capacitance
Point level detection
Minicap FTC262

Minicap FTC262 plastic housing ©Endress+Hauser
Minicap FTC262 aluminium housing ©Endress+Hauser
Minicap FTC262 application ©Endress+Hauser

Designed for light bulk solids

Minicap FTC262 is a simple and cost-effective rope probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

  • Benefícios

    • Simple mounting and commissioning without calibration

    • Mechanical safety, cost-efficiency and long operating life due to no wearing parts

    • High operational safety and reliability due to active build-up compensation

    • Optimized storage by simply shortening the...

  • Campo de aplicação

    For point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6.
    Typical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

    • Process connection: Threads

    • ...

Características e especificações

Voltar

Details

  • Measuring principle

    Capacitive Solid

  • Characteristic / Application

    No calibration on start-up
    Active build-up compensation
    Mechanically robust
    The rope probe can be shortened
    (optimum matching to the measuring point)

  • Specialities

    Rope shortening parts to be supplied by the customer

  • Supply / Communication

    10,8 ... 45V DC, DC-PNP 3-wire
    20 ... 253V AC, or
    20 ... 55V DC, Relay output

  • Ambient temperature

    -40 °C ... 80 °C(-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    -1 ... 6 bar(-14.5 ... 90 psi)

  • Main wetted parts

    PPS = Polyphenylene sulphide
    (glass fibre content approx. 40%)

  • Max. tensile strength

    3000 N

  • Process connection

    R 1 1/2
    NPT 1 1/2

  • Sensor length

    min. 500 mm (20"), max 6000 mm (236")

  • Communication

    PNP transistor output
    Relay output (potential-free
    change-over contact / SPDT)

  • Certificates / Approvals

    ATEX , FM, CSA, NEPSI, EAC

  • Options

    Aluminium Housing

  • Application limits

    Solids, grain size max. 30 mm (1.2"),
    DK min 1,5
    Flexural strength 1400 N (at probe tip)

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification
  • Predecessor