Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
t90 starting at < 1,5 s iTHERM QuickSens depending on configuration
Max. process pressure (static)
depending on the configuration
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 basic TF: -50 °C ...200 °C (-58 °F ...392 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
iTHERM ModuLine TM112 is a modular imperial RTD or TC thermometer with direct contact (without thermowell). It is suitable for every application, from basic functionality to high-end performance across all industries.
For universal use across all industries: From heavy industries (Power & Energy, Chemical, Oil & Gas) to utility applications.
International certification: e.g. explosion protection according to ATEX, IECEx, CSA C/US and NEPSI.
iTEMP temperature transmitter with all common communication protocols and optional Bluetooth® connectivity.
Benefícios
Modular configuration for all applications: A wide selection of components and innovations, all combined under a single order code.
Increased efficiency: Fastest response times with iTHERM QuickSens sensor design.
Enhanced safety: Reliability in demanding applications with iTHERM StrongSens and highest vibration-resistance.
Torishima projeta e constrói grandes sistemas de água de resfriamento para clientes no Oriente Médio, confiando na instrumentação da Endress+Hauser pela qualidade e desempenho de seus produtos.
Ao integrar um sensor de temperatura com poço para termoelemento iTHERM TwistWell com design helicoidal avançado, os operadores podem alcançar uma qualidade de vapor superior e reduzir significativamente as vibrações induzidas por vórtice.
Garanta o tempo de atividade do data center e reduza os custos de energia usando equipamentos de temperatura precisos com RTDs sólidos de 3 ou 4 fios e transmissores de temperatura inteligentes em aplicações de refrigeração de líquidos.
Explore iTHERM ModuLine industrial thermometers and thermowells. Learn more about the technical differences between the different models and discover included Endress+Hauser innovations.
O iTHERM ModuLine oferece flexibilidade total para medição de temperatura industrial. Os sensores de temperatura industriais modulares podem ser configurados individualmente para atender às necessidades do seu processo.
imperial style universal range of application suitable for hazardous areas can be used with iTHERM StrongSens, iTHERM QuickSens direct process contact
Thermowell / protection tube
without, direct process contact
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
Insert: 1/8" 1/4" 3/8" 3/8" reduziert auf 3/16" 3,0 mm 6,0 mm
Max. immersion length on request
up to 180"
Material protection tube/ thermowell
Insert Material: 316L (1.4404) Alloy 600 (2.4816)
Process connection
Thread: NPT1/2", NPT3/4" Compression fitting, also spring load: NPT1/4", NPT1/2"
Tip shape
straight stepped
Surface roughness Ra
0,76 μm (30 μin.) 1,6 μm (63,0 μin.)
Operating temperature range
PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 TF iTHERM QuickSens: -50 °C …200 °C (-58 °F …392 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 basic TF: -50 °C ...200 °C (-58 °F ...392 °F) Typ K: max. 1.100 °C (max. 2.012 °F) Typ J: max. 800 °C (max. 1.472 °F) Typ N: max. 1.100 °C (max. 2.012 °F)
Max. process pressure (static)
depending on the configuration
Accuracy
Class AA acc. to IEC 60751 Class A acc. to IEC 60751 Class B acc. to IEC 60751 Class special or standard acc. to ASTM E230 Class 1 or 2 acc. to IEC 60584-2
Response time
t90 starting at < 1,5 s iTHERM QuickSens depending on configuration
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
ATEX Ex ec ATEX IECEx Ex ia CSA C/US IS, NI, XP, DIP INMETRO Ex ia
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
WirelessHART communication interface Transmission rate: Nominal 250 kBits/s Operating frequency: 2.4 GHz (ISM band) Transmission range under reference conditions: Outdoor 250 m, indoor 50 m
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Usamos cookies para melhorar sua experiência de navegação, coletamos estatísticas para otimizar a funcionalidade do site e entregar anúncios e conteúdo personalizados.
Ao selecionar "Aceitar todos", você consente nosso uso de cookies.
Para mais detalhes, revise nossa Política de cookies .