Radiometric
Level/density measurement
Source Container FQG62

Source Container FQG62 ©Endress+Hauser
Source Container FQG62 ©Endress+Hauser
Source Container FQG62 ©Endress+Hauser

Radiometric measuring principle

Animation source containers

Animation Gamma Modulator

Radiation source container with source holder for manual or pneumatic switch-on/switch-off

The FQG62 source container is designed to hold the radioactive source during radiometric point level detection, continuous level and density measurement. The radiation is emitted almost unattenuated in one direction only, and is damped in all other directions. This guarantees highest safety for the personnel and a reliable measurement.

  • Benefícios

    • High safety level thanks to highest classification for the source supplied (DIN 25426/ISO 2919, typically classification C66646) and safe and easy source replacement

    • Reliable measurement due to lightweight container and almost spherical design which...

  • Campo de aplicação

    Designed to hold the radioactive source during radiometric point level detection, continuous level measurement and density measurement. Radiation is emitted almost unattenuated in one direction only, and is damped in all other directions.

    • Activity:...

Details

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    Approximately 87kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Certificates / Approvals

    ATEX, GOST

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    Approximately 87kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Certificates / Approvals

    ATEX, GOST

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    Approximately 87kg

  • Specialities

    Manual or pneumatic switch-on/ switch-off

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Certificates / Approvals

    ATEX, GOST

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    Approximately 87kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F ...+392 °F)

  • Process temperature

    Any

  • Process pressure absolute / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Certificates / Approvals

    ATEX, GOST

  • Measuring principle

    Radiometric Density

  • Characteristic / Application

    Source container
    Emission angle: 5/ 20/ 40 degrees
    87kg

  • Ambient temperature

    -20 °C...+200 °C

    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure absolute

    Any

  • Wetted parts

    Non-contact

  • Hygienic

    Non-contact

  • Specialities

    Control area calculation with Applicator

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification