Campo de aplicação
FlexView FMA90 is a control unit for radar, ultrasonic and hydrostatic or universal 4-20 mA or HART level sensors. It connects up to two sensors simultaneously and provides 8 digital switching outputs for enhanced control. Available in field, DIN rail and panel housing variants, it ensures flexible installation in the field or control cabinet. Its robust design and intuitive touch operation make it ideal for water and wastewater as well as mining, minerals and metals applications.
FlexView FMA90 is suitable for a wide range of applications, providing clear visualization of measurement data and enhanced process control:
Open channel flow measurement
Remote water level and temperature monitoring
Pump control in water and wastewater treatment
Differential level measurement for rake control
Level monitoring in bulk solids storage
Crusher and conveyor belt monitoring
Benefícios
Flexible use with up to two level sensors across multiple measurement technologies and seamless system integration via HART or Modbus TCP
High cybersecurity in line with IEC 62443 and Endress+Hauser ProtectBlue product security framework
Remote access and parameterization at hard-to-reach measurement points via Wi-Fi and an integrated web server
Intuitive operation thanks to the 3.5" color touch display operable with gloves
Fast commissioning with automatic sensor detection and configuration via HART and guided setup sequences
Predecessor
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
| Versões FLEX | Excelência técnica | Simplicidade |
|---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
Measuring principle
Hydrostatic pressure
-
Characteristic
Level, pump control, open channel flow measurement, data logging, rake control, storm overflow basin
-
Supply voltage
100 … 230 VAC;
10.5 … 32 VDC -
Ambient temperature
-40 to +60 °C (-40 to +140 °F) (Type tested);
-35 to +60 °C (-31 to +140 °F) (approved by CSA) -
Communication
Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN) -
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC
-
Specialities
Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors
-
Measuring principle
Level radar
-
Characteristic / Application
Level, pump control, open channel flow measurement, data logging, rake control, storm overflow basin
-
Specialities
Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors -
Supply / Communication
100 … 230 VAC;
10.5 … 32 VDC -
Ambient temperature
-40 to +60 °C (-40 to +140 °F) (Type tested);
-35 to +60 °C (-31 to +140 °F) (approved by CSA) -
Communication
Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN) -
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC
-
Options
3.5" TFT touch color display for onsite operation with backlight, WLAN connectivity or communication via Ethernet, guided wizzards vor commissioning, up to two level sensors
Housing:
Panel-mounted / DIN rail / Field -
Components
Sensors: FMR10B, FMR20B, FMR30B, FMX21, FMU30
-
Measuring principle
Level radar solid
-
Characteristic / Application
Level, pump control,open channel flow measurement, data logging, rake control, storm overflow basin
-
Specialities
Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors -
Supply / Communication
100 … 230 VAC;
10.5 … 32 VDC -
Ambient temperature
–40 to +60 °C (–40 to +140 °F) (Type tested);
–35 to +60 °C (–31 to +140 °F) (approved by CSA) -
Communication
Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN) -
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO, KC
-
Options
3.5" TFT touch color display for onsite operation with backlight, WLAN connectivity or communication via Ethernet, guided wizzards vor commissioning, up to two level sensors
Housing:
Panel-mounted / DIN rail / Field -
Components
Sensors: FMR10B, FMR20B, FMR30B, FMX21, FMU30
-
-
Informações Técnicas (TI)
TI FlexView FMA90
-
Informações Técnicas (TI)
Versão em português - 05/2025New version available in EnglishUnidade de controle
EN PT 22/06/202631/05/202524/12/2022Idioma:
Português
Versão:
31/05/2025
Tamanho do arquivo:
4.2 MB
Nome do arquivo:
TI01689FPT_0225-00.pdf
-
-
-
Instruções de Operação (BA)
BA FlexView FMA90
-
Instruções de Operação (BA)
Versão em português - 06/2026New version available in EnglishUnidade de controle com display colorido e controle touchscreen para até 2 sensores de nível ultrassônico, radar, hidrostático ou un
iversal 4-20 mA/HART®EN PT 22/06/2026Idioma:
Português
Versão:
22/06/2026
Tamanho do arquivo:
10.9 MB
Nome do arquivo:
BA02604FPT_0126-00.pdf
-
-
-
Instruções de Operação (BA)
BA FlexView FMA90
-
Instruções de Operação (BA)
Versão em inglês - 06/2026New version available in EnglishControl unit for level and flow measurements
Modbus TCP server communicationEN PT 30/06/2026Idioma:
Inglês
Versão:
30/06/2026
Tamanho do arquivo:
11.3 MB
Nome do arquivo:
BA02603FEN_0126-00.pdf
-
-
-
Instruções de Operação (BA)
BA FlexView FMA90
-
Instruções de Operação (BA)
Versão em português - 06/2026New version available in EnglishUnidade de controle com display colorido e controle touchscreen para até 2 sensores de nível ultrassônico, radar, hidrostático ou un
iversal 4-20 mA/HART®EN PT 22/06/202629/12/2022Idioma:
Português
Versão:
22/06/2026
Tamanho do arquivo:
10.9 MB
Nome do arquivo:
BA02254FPT_0226-00.pdf
-
-
-
Parâmetro do Equipamento (GP)
GP FlexView FMA90
-
Parâmetro do Equipamento (GP)
Versão em inglês - 07/2026New version available in EnglishControl unit for level and flow measurements
EN PT 31/07/202601/12/2024Idioma:
Inglês
Versão:
31/07/2026
Tamanho do arquivo:
1.7 MB
Nome do arquivo:
GP01189FEN_0226-00.pdf
-
-
-
Parâmetro do Equipamento (GP)
GP FlexView FMA90
-
Parâmetro do Equipamento (GP)
Versão em inglês - 06/2026New version available in EnglishControl unit for level and flow measurements
With Modbus TCP server communicationEN PT 30/06/2026Idioma:
Inglês
Versão:
30/06/2026
Tamanho do arquivo:
1.9 MB
Nome do arquivo:
GP01260FEN_0126-00.pdf
-
-
-
Parâmetro do Equipamento (GP)
GP FlexView FMA90
-
Parâmetro do Equipamento (GP)
Versão em inglês - 06/2026New version available in EnglishControl unit for level and flow measurements
HART outputEN PT 30/06/2026Idioma:
Inglês
Versão:
30/06/2026
Tamanho do arquivo:
1.9 MB
Nome do arquivo:
GP01259FEN_0126-00.pdf
-
-
-
Instruções curtas (KA)
KA FlexView FMA90
-
Instruções curtas (KA)
Versão em português - 06/2026New version available in EnglishUnidade de controle com display colorido e controle touchscreen para até 2 sensores de nível ultrassônico, radar, hidrostático ou un
iversal 4-20 mA/HART®EN PT 30/06/202631/05/202530/05/2025Idioma:
Português
Versão:
30/06/2026
Tamanho do arquivo:
4.7 MB
Nome do arquivo:
KA01584FPT_0526-00.pdf
-
-
-
Instruções de Instalação (EA)
EA Front+Display FMA90 DIN Rail
-
Instruções de Instalação (EA)
Versão em inglês - 11/2025New version available in EnglishEinbauanleitung für Front+Display FMA90 DIN Rail
EN PT 20/11/202519/11/2025Idioma:
Inglês
Versão:
20/11/2025
Tamanho do arquivo:
4 MB
Nome do arquivo:
EA_Front_Display_71706829_71706830_DIN Rail_en_we.pdf
-
-
-
Instruções de Instalação (EA)
EA CPU-Board FMA90 Panel
-
Instruções de Instalação (EA)
Versão em inglês - 11/2025New version available in EnglishEA CPU-Board FMA90 Panel
Idioma:
Inglês
Versão:
19/11/2025
Tamanho do arquivo:
4 MB
Nome do arquivo:
EA_CPU_FMA90_Panel_XPF0053_en_we.pdf
-
Escolha uma das opções sugeridas
-
-- selected coding-- selected label99.999,00<%label%>
-
Procurando mais opções? Use o configurador individual para continuar.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Procurando mais opções? Use o configurador individual para continuar.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Diagramas CAD Diagramas CAD
- Diagramas CAD
-
Preço por peça
-
<%range%><%price%>
-
- Acessórios opcionais
Configuração individual
Geralmente são fornecidos juntos
Acessórios
Produtos relacionados