Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
-
Output / communication
1/2 x 4 to 20 mA, HART, Profibus, FF
Additional second output possible, also later -
Ingress protection
IP66/67, NEMA 4X
Campo de aplicação
Liquiline M CM42 is the robust transmitter for pH/ORP, conductivity or oxygen measurement in all process applications. It is the best choice for demanding environments be it hygienic applications, hazardous areas or functional safety areas. Liquiline’s intuitive operating concept simplifies commissioning, handling, and maintenance saving you time every day. Easy switching of parameters and seamless system integration give you the flexibility to adapt it exactly to your measuring task.
The Liquiline CM42 transmitter is suitable for all process applications, for example in these industries and their utilities:
Chemicals
Food & Beverages
Life Sciences
Power & Energy
Oil & Gas
Primaries & Metal
Liquiline CM42 features the following protocols and interfaces:
0/4...20 mA
HART
PROFIBUS PA
FOUNDATION Fieldbus
With its international explosion protection approvals, such as IECEx, ATEX, FM, CSA, TIIS and NEPSI, the transmitter is suitable for hazardous area use.
Benefícios
Simple commissioning with quick setup and navigator
The Memosens technology allows plug & play with pre-calibrated Memosens sensors
Less storage thanks to modular design
Predictive maintenance system detects when a sensor has to be cleaned, calibrated or replaced
Vídeos
-
Memosens converts the measured value to a digital signal and transfers it to the transmitter without a contacting connection. This video shows how Memosens optimizes process control and maintenance.
Predecessor
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
| Versões FLEX | Excelência técnica | Simplicidade |
|---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
Measuring principle
ISFET
-
Application
Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
-
Characteristic
Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
-
Measuring principle
Potentiometric pH measurement
-
Design
Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
-
Material
Plastic or stainless steel housing with EPDM sealings
-
Dimension
Plastic housing:
144 x 144 x 148 mm
5.67 x 5.67 x 5.83 inch
Stainless Steel:
174 x 174 x 134 mm
6.85 x 6.85 x 5.28 inch -
Temperature sensor
Applicable:
Pt100, Pt1000, NTC 30K -
Ex certification
: ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
-
Ingress protection
IP66/67, NEMA 4X
-
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
-
Output / communication
1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later
-
Measuring principle
Sensor ORP / Redox
-
Application
Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
-
Characteristic
Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
-
Measuring principle
ORP measurement
-
Design
Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
-
Material
Plastic or stainless steel housing with EPDM sealings
-
Dimension
Plastic housing:
144 x 144 x 148 mm
5.67 x 5.67 x 5.83 inch
Stainless Steel:
174 x 174 x 134 mm
6.85 x 6.85 x 5.28 inch -
Temperature sensor
Applicable:
Pt100, Pt1000, NTC 30K -
Ex certification
ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
-
Ingress protection
IP66/67, NEMA 4X
-
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
-
Output / communication
1/2 x 4 to 20 mA, HART, Profibus, FF
Additional second output possible, also later
-
Measuring principle
Conductive
-
Application
Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
-
Characteristic
Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
-
Measuring principle
Resistance measurement
-
Design
Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
-
Material
Plastic or stainless steel housing with EPDM sealings
-
Dimension
Plastic housing:
144 x 144 x 148 mm
5.67 x 5.67 x 5.83 inch
Stainless Steel:
174 x 174 x 134 mm
6.85 x 6.85 x 5.28 inch -
Temperature sensor
Applicable:
Pt100, Pt1000 -
Ex certification
ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
-
Ingress protection
IP66/67, NEMA 4X
-
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
-
Output / communication
1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later
-
Measuring principle
Amperometric oxygen measurement
-
Application
Chemical processes, pharmaceuticals industry, foodstuff technology, applications in hazardous areas
-
Characteristic
Liquiline M CM42 is a modular two-wire transmitter for all areas of process engineering
-
Measuring principle
Connection of oxygen sensors with Memosens coupling
-
Design
Depending on the ordered version, Liquiline M CM42 has one or two analog current outputs or it can be connected to field busses as per FOUNDATION Fieldbus, PROFIBUS PA and HART protocol
-
Material
Plastic or stainless steel housing with EPDM sealings
-
Dimension
Plastic housing:
144 x 144 x 148 mm
5.67 x 5.67 x 5.83 inch
Stainless Steel:
174 x 174 x 134 mm
6.85 x 6.85 x 5.28 inch -
Ex certification
ATEX, IECEx, FM, CSA, NEPSI, EAC, UKEx, JPN Ex
-
Ingress protection
IP66/67, NEMA4X
-
Input
One channel transmitter for Memosens and analog (pH, ORP, conductivity)
-
Output / communication
1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later
-
-
Informações Técnicas (TI)
TI Liquiline M CM42
-
Informações Técnicas (TI)
Versão em português - 08/2025New version available in EnglishTransmissor de dois fios para áreas classificadas e não classificadas
EN PT 18/08/202515/10/202025/06/201425/06/201301/01/2011Idioma:
Português
Versão:
18/08/2025
Tamanho do arquivo:
4.5 MB
Nome do arquivo:
TI00381CPT_1725-00.pdf
-
-
-
Instruções curtas (KA)
Liquiline CM42
-
Instruções curtas (KA)
Versão em português - 01/2021New version available in EnglishTransmissor de dois fios para pH/ORP, condutividade ou oxigênio
EN PT 31/05/202131/01/2021Idioma:
Português
Versão:
31/01/2021
Tamanho do arquivo:
3.6 MB
Nome do arquivo:
KA01481CPT_0121.pdf
-
-
-
Instruções de Segurança Ex (XA)
XA Liquiline M CM42
-
Instruções de Segurança Ex (XA)
Versão em inglês - 07/2025New version available in EnglishTwo-wire transmitter for hazardous areas
EAC 1Ex ib [ia Ga] IIC T6/T4 Gb XEN PT 28/07/202501/01/202130/04/2016Idioma:
Inglês
Versão:
28/07/2025
Tamanho do arquivo:
429.1 KB
Nome do arquivo:
XA01504CEN_0325-00.pdf
-
-
-
Instruções de Segurança Ex (XA)
Liquiline M CM42
-
Instruções de Segurança Ex (XA)
Versão em inglês - 10/2021New version available in EnglishSupplement to: BA00381C
Safety instructions for electrical apparatus in explosion-hazardous
areas
UK Ex II (1)2G Ex ib[ia Ga] IICT6/T4 GbIdioma:
Inglês
Versão:
29/10/2021
Tamanho do arquivo:
939.2 KB
Nome do arquivo:
XA02725CEN_0121.pdf
-
-
-
Instruções de Segurança Ex (XA)
Liquiline M CM42
-
Instruções de Segurança Ex (XA)
Versão em inglês - 06/2022New version available in EnglishNEPSI Ex ib [ia Ga] IIC T4/T6 Gb
Safety instructions for electrical apparatus in explosion-hazardous
areasEN PT 13/06/2022Idioma:
Inglês
Versão:
13/06/2022
Tamanho do arquivo:
534.9 KB
Nome do arquivo:
XA02858CEN_0122-00.pdf
-
-
-
Instruções de Segurança Ex (XA)
XA Liquiline M CM42
-
Instruções de Segurança Ex (XA)
Versão em inglês - 12/2023New version available in EnglishTwo-wire transmitter for hazardous areas
KOR Ex ib [ia Ga] IIC T6/T4 GbEN PT 08/12/202311/07/2023Idioma:
Inglês
Versão:
08/12/2023
Tamanho do arquivo:
422.5 KB
Nome do arquivo:
XA03133CEN_0223-00.pdf
-
-
-
Instruções de Segurança Ex (XA)
XA Liquiline M CM42
-
Instruções de Segurança Ex (XA)
Versão em português - 05/2025New version available in EnglishTransmissor de dois fios para áreas classificadas
ATEX II 3G Ex ec [ic Gc] IIC T6 Gc
NEPSI Ex ec [ic Gc] IIC T6 GcEN PT 27/05/2025Idioma:
Português
Versão:
27/05/2025
Tamanho do arquivo:
537.6 KB
Nome do arquivo:
XA03517CPT_0125-00.pdf
-
-
-
Instruções de Segurança Ex (XA)
Liquiline M CM42
-
Instruções de Segurança Ex (XA)
Versão em inglês - 03/2023New version available in EnglishTwo-wire transmitter for hazardous areas
JPN Ex ib [ia Ga] IIC T6 GbEN PT 29/03/2023Idioma:
Inglês
Versão:
29/03/2023
Tamanho do arquivo:
420.9 KB
Nome do arquivo:
XA03099CEN_0123-00.pdf
-
-
-
Instruções de Segurança Ex (XA)
XA Liquiline M CM42
-
Instruções de Segurança Ex (XA)
Versão em português - 10/2024New version available in EnglishTransmissor de dois fios para áreas classificadas
INMETRO Ex ib [ia Ga] IIC T6/T4 GbEN PT 31/10/2024Idioma:
Português
Versão:
31/10/2024
Tamanho do arquivo:
441 KB
Nome do arquivo:
XA03395CPT_0124-00.pdf
-
-
-
Instruções de Segurança Ex (XA)
XA Liquiline CM42
-
Instruções de Segurança Ex (XA)
Versão em inglês - 12/2023New version available in EnglishTwo-wire transmitter for hazardous areas
FM IS NI Cl.I Div.1&2, Groups A-D
CSA IS NI Cl.I,II,III Div.1&2, Groups A-GEN PT 14/12/202329/11/202101/07/202131/07/202028/02/2019Idioma:
Inglês
Versão:
14/12/2023
Tamanho do arquivo:
1.2 MB
Nome do arquivo:
XA01687CEN_0623-00.pdf
-
Escolha uma das opções sugeridas
-
-- selected coding-- selected label99.999,00<%label%>
-
Procurando mais opções? Use o configurador individual para continuar.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Procurando mais opções? Use o configurador individual para continuar.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Diagramas CAD Diagramas CAD
- Diagramas CAD
-
Preço por peça
-
<%range%><%price%>
-
- Acessórios opcionais
Configuração individual
Geralmente são fornecidos juntos
Acessórios
Produtos relacionados