Phosphorus is the decisive factor for excessive algae and plant growth in water bodies, that's why continuous monitoring of this parameter is essential. The Liquiline System TP analyzer offers precise online measurement of total phosphorus and ensures highest process safety. Automatic calibration and cleaning save you operating costs while advanced diagnostics with remote access support you in providing process documentation to the authorities.
The Liquiline System TP analyzer monitors:
Inlet and outlet of wastewater treatment plants for documentation purposes and calculation of the cleaning capacity
Discharges of industrial wastewater treatment plants to determine discharge fees and to support the polluter-pays-principle
Process water
Benefícios
Molybdenum blue method according to EN ISO 6878:2004 guarantees direct comparability to laboratory results
Meeting industry needs: The analyzer is perfectly suited for environmental monitoring, industrial and municipal wastewater
Fast and easy process integration: Direct installation of self-priming version or y-strainer for bypass applications
Safety on the highest level: Software-controlled safety cover for the reactor and all heated parts. Additional safety light barrier prevents overdosing of reagents and sample.
Combination of reliable sample delivery and high-precision dosing: Peristaltic pumps are able to cope with particles in the sample. Light barriers enable precise, reproducible dosing.
Enhanced reagent lifetime thanks to optional cooling module
Easy upgrade of functionality to a complete measuring station - simply by adding modules and connecting Memosens sensors.
Endress+Hauser enables fast and reliable water analysis at Butoniga Reservoir, ensuring optimal layer selection, improved water quality and reduced operating costs.
A AVR Waste em Botlek, Rotterdam, processa até 1,7 milhão de toneladas de resíduos residuais por ano. Descubra como eles otimizam a medição de pH graças à Endress+Hauser
Uso de água do mar nas descargas de banheiro pode economizar muita água potável. Para garantir um fornecimento constante de água, os sensores usados devem funcionar de forma confiável para atender os objetivos de qualidade da água (WQO).
Flexibilidade e boa ergonomia são particularmente importantes na produção de sistemas pesados. Nossas modernas linhas de produção oferecem a nossa equipe o melhor suporte possível para entregar produtos de alta qualidade.
Ao escolher a plataforma Liquiline, você opta por gastar menos dinheiro na manutenção do estoque, economizar tempo de instalação e obter segurança da operação!
Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in
Design
Open design, cabinet and stand housing High-Performance plastic ASA-PC, additional stand coated steel
Process temperature
4 to 40 °C (39.2 to 104 °F)
Ambient temperature
5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Process pressure
At atmospheric pressure, < 0.2 bar
Sample flow rate
Min. 30 ml/min
Consistency of the sample
Low solid content (TS<50 mg/l), homogeneous
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors Automatic calibration and cleaning User-configurable measuring, cleaning and calibration intervals Self-priming analyzer with optical dosing unit l Dilution module (optional) Digital communication for remote access
Application
Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants Monitoring of the wastewater treatment plant outlet for documentation purposes Monitoring and optimization of activated sludge basins
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1,2 Hz
Output / communication
2x 0/4 to 20 mA Webserver, Modbus, Ethernet/IP, Profibus DP
Input
1 measuring channel 1 to 4 digitale sensor inputs for sensors with Memosens protocol (optional)
Measuring range
0 to 2 mg/l 0.05 to 10 mg/l 0.5 to 50 mg/l
Consumables
Reagents and standard solutions CY80TP are necessary for the operation
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Ensure optimal CA80 analyzer performance with expert commissioning and first year preventive maintenance service for seamless operation and reduced downtime
Usamos cookies para melhorar sua experiência de navegação, coletamos estatísticas para otimizar a funcionalidade do site e entregar anúncios e conteúdo personalizados.
Ao selecionar "Aceitar todos", você consente nosso uso de cookies.
Para mais detalhes, revise nossa Política de cookies .