Specs at a glance
-
Process temperature
-60°C...+280°C
(-76°F...+540°F) -
Process pressure / max. overpressure limit
Vacuum...100 bar
(1450 psi) -
Min. density of medium
Density from 0.4 g/cm3
(0.4 SGU)
Field of application
Liquiphant FTL81 is a point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for liquids up to SIL3.
Process connections: Threads and flanges
Temperature: -60 to +280°C (-76 to +540°F)
Pressure: -1 to +100bar (-14.5 to +1,450psi)
Sensor length: Extension pipe up to 3m (9.8ft)
Sensor material: 316L, Alloy C
International explosion protection certificates, overfill protection WHG, SIL, marine approvals
Benefits
Use in safety systems requiring functional safety to SIL3 in accordance with DIN EN IEC 61508 Ed.2.0 and DIN EN ISO 13849
Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
Permanent self-monitoring/internal redundancy
4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC
No adjustment: quick, low-cost startup
No mechanically moving parts: no maintenance, no wear, long operating life
Monitoring of fork for damage, corrosion, build-up and mechanical blocking
Videos
-
Vibronic measuring principle
-
Functional safety SIL in process instrumentation
-
Liquiphant with permanent function check is the safe choice for point level detection in liquids
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
Success stories
-
Measuring principle
Vibration Liquids
-
Characteristic / Application
Reliable point level switch with extension pipe for MIN and MAX safety applications up to SIL3.
Dual Sealing / Second line of defense
Modular housing concept -
Specialities
Outstanding features:
- permanent LIVE signal
monitors function safety
- failsafe design and
- high availability of the measuring values -
Supply / Communication
2-wire 4...20 mA
-
Ambient temperature
-60°C...+70°C
(-76°F...+160°F) -
Process temperature
-60°C...+280°C
(-76°F...+540°F) -
Process pressure / max. overpressure limit
Vacuum...100 bar
(1450 psi) -
Min. density of medium
Density from 0.4 g/cm3
(0.4 SGU) -
Main wetted parts
316L
Alloy C -
Process connection
Flange:
DN25...DN100,
ASME 1"...4",
JIS 10K...20K
Thread:
G3/4, G1, R3/4,
R1, MNPT3/4, MNPT1 -
Sensor length
Extension pipe up to 3 m (9.8 ft)
-
Communication
2-wire 4...20 mA
-
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC
-
Safety approvals
Overfill protection WHG
Leakage Detection
SIL3 -
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3
AD2000 -
Marine approval
GL/ ABS/ LR/ BV/ DNV
-
Options
PWIS free
Pressure tight feed through
Weather protection -
Components
Nivotester FTL825, Transmitter
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
-
Technical Information (TI)
English version - 12/2024Level, pressure and temperature measurement
EN 06/12/202425/03/202415/09/202328/10/202130/07/2021Language:
English
Version:
06/12/2024
File size:
1.3 MB
File name:
TI00426FEN_2624.pdf
-
-
-
Technical Information (TI)
Liquiphant FailSafe FTL80, FTL81, FTL85 Technical Information
-
Technical Information (TI)
English version - 06/2013Vibronic
Point level switch for liquidsEN 04/06/201316/07/2012Language:
English
Version:
04/06/2013
File size:
678.4 KB
File name:
TI01026FEN_0213.pdf
-
-
-
Operating Instruction (BA)
Liquiphant FailSafe FTL80, FTL81, FTL85 Operating Instructions
-
Operating Instruction (BA)
English version - 06/2013Vibronic
Point level switch for liquidsEN 04/06/201316/07/2012Language:
English
Version:
04/06/2013
File size:
768.4 KB
File name:
BA01037FEN_0213.pdf
-
-
-
Short Instruction (KA)
Liquiphant M/S FTL51, FTL71, FTL81 Operating Instructions
-
Short Instruction (KA)
English version - 05/2017High Pressure Sliding Sleeve
G 1, NPT 1EN 09/05/201731/07/201001/05/200801/10/2005Language:
English
Version:
09/05/2017
File size:
295.4 KB
File name:
KA00153FA6_1317.pdf
-
-
-
Short Instruction (KA)
Liquiphant M/S FTL51, FTL71, FTL81
-
Short Instruction (KA)
English version - 05/2017High Pressure Sliding Sleeve
G 1 1/2, NPT 1 1/2EN 09/05/201731/07/201001/05/200813/10/2005Language:
English
Version:
09/05/2017
File size:
280 KB
File name:
KA00154FA6_1317.pdf
-
-
-
Short Instruction (KA)
Operating Instuction Liquiphant M FTL 51, FTL71, FTL81
-
Short Instruction (KA)
English version - 05/2017Sliding Sleeve G 1 A, 1 NPT
for Unpressurised Operation.EN 09/05/201719/10/2005Language:
English
Version:
09/05/2017
File size:
158.9 KB
File name:
KA00151FA6_1317.pdf
-
-
-
Short Instruction (KA)
Operating Instuction Liquiphant FTL 51, FTL71, FTL81 Sliding Sleeve
-
Short Instruction (KA)
English version - 05/2017Sliding Sleeve G 1½ A, 1½ NPT
for Unpressurised Operation.EN 09/05/201719/10/2005Language:
English
Version:
09/05/2017
File size:
141.4 KB
File name:
KA00152FA6_1317.pdf
-
-
-
Installation Instructions (EA)
Cover for housing T13 electronic compartment Installation instruction
-
Installation Instructions (EA)
English version - 08/2014Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN 11/08/201409/08/2012Language:
English
Version:
11/08/2014
File size:
164.3 KB
File name:
EA01048FA2_0214.pdf
-
-
-
Installation Instructions (EA)
Cover for housing F13 Installation instruction
-
Installation Instructions (EA)
English version - 08/2014Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN 11/08/201409/08/2012Language:
English
Version:
11/08/2014
File size:
134.4 KB
File name:
EA01046FA2_0214.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .