Liquiphant FTL51 is a point level switch with extension tube for use in hazardous areas with all international certificates. Useable in all industries. FTL51 offers functional safety SIL2/SIL3. With the second line of defense highest degree of safety and availability of the device can be guaranteed. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch with extension tube for all liquids.
Process connections: Threads, flanges and hygienic process connection (Tri-Clamp)
Temperature: -50 to +150°C (-58 to +302°F)
Pressure: -1 to +100bar (-14.5 to +1,450psi)
Sensor material: 316L, Alloy
International explosion protection certificates, overfill protection WHG, SIL
Benefits
Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with IEC 61508/IEC 61511-1
International explosion protection certificates and overfill protection certificate (WHG)
No calibration required, easy to start up
No mechanically moving parts: no maintenance, no wear, long operating life. Monitoring of fork for damage: guaranteed function
Second line of defense to protect the environment
Variety of standardized process connections for all applications
Stainless steel (316L) and high-corrosion resistant sensor material (Alloy)
Protolaunch uses Endress+Hauser flowmeters and level sensors at a rocket propulsion test facility in Buckinghamshire to demonstrate the performance of the propulsion systems and components.
Messer produces hydrogen in a steam reformer. The facility has a large number of protection and safety devices where pressure values play an important role.
The Egyptian government is working to replace liquid fuels with natural gas. To achieve this they targeted increasing the number of CNG stations in their country from 306 to 1000 by the end of 2021.
Modular housing concept wide range of process connections Analogue and bus interfaces Extensive certificate range (e.g. Ex,WHG) pipe extension up to 3m (6m option)
Specialities
Foamdetection Detect a densitychange second line of defense
Supply / Communication
PROFIBUS PA 19...253V AC 10...55V DC-PNP 19...253V AC or 10...55V DC 8/16mA, 11...36V DC NAMUR PFM
Liquiphant M Density with Density Computer FML621 Temperature and pressure measurement Modular housing concept Wide range of process connections Pipe extension up to 3 m (6 m option)
Supply / Communication
Transmitter power supply (MUS)
Ambient temperature
-50...70°C -50...60°C for hazardous applications
Process temperature
0...80°C (validity of accuracy data) -50...0°C / 80...150 °C (with reduced technical data)
Process pressure
0...25 bar >25..100 bar (with reduced technical data)
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex