Proline Promag 53P
Electromagnetic flowmeter

Electromagnetic flowmeter - Proline Promag 53P ©Endress+Hauser

The Electromagnetic Flow Measuring Principle

The flowmeter for highest medium temperatures with flexible system integration

Promag P is the preferred sensor for applications with highest requirements in a multitude of industries. Combined with the Promag 53 transmitter with touch control, four line display and extended functionality like software options for filling and dosing, electrode cleaning or advanced diagnostics, Promag 53P offers highest accuracy in the most complex and demanding measuring tasks. It is dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

  • Benefícios

    • Versatile applications – wide variety of wetted materials

    • Energy-saving flow measurement – no pressure loss due to cross-section constriction

    • Maintenance-free – no moving parts

    • Quality – software for filling and dosing, density, electrode cleaning and also...

  • Campo de aplicação

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity

    • Dedicated to chemical and process applications with corrosive liquids and high medium temperatures

    Device properties

    • Nominal diameter: max....

Características e especificações

Voltar

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    The flowmeter for highest medium temperatures with flexible system integration. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

  • Sensor features

    Versatile applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex-approvals.

  • Transmitter features

    Quality – software for filling & dosing, density, electrode cleaning and also advanced diagnostics. Easy calculation – bidirectional totalizers. Automatic recovery of data for servicing. 4-line backlit display with touch control. Device as compact or remote version.

  • Nominal diameter range

    DN 15...600
    1/2"...24"

  • Max. measurement error

    ±0.2%

  • Measuring range

    0...9'600 m3/h

  • Max. process pressure

    PN10...40
    Cl 150...300
    JIS 10...20K
    AS 2129 Table E
    AS 4087 PN16

  • Medium temperature range

    -40...+180°C
    (-40...+356°F)

  • Ambient temperature range

    -20...+60°C
    -40...+60°C (optional)

  • Degree of protection

    IP 67 (NEMA 4x)
    IP 68 (Nema 6P)

  • Display/Operation

    Four line display with backlit
    Touch control

  • Outputs

    4...20 mA
    Pulse / frequenz (aktive/passive)
    Relays
    Status

  • Inputs

    Status
    Current input

  • Digital communication

    HART
    PROFIBUS PA
    Profibus DP
    FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX, FM, CSA, TIIS

  • Product safety

    CE, C-tick, EAC marking

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification
  • Predecessor

  • Successor