Características e especificações

Voltar

Details

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    US style
    modular temperature assembly
    for heavy duty applications
    suitable for hazardous areas
    with neck
    incl. thermowell / protection tube (metal)

  • Thermowell / protection tube

    welded protection tube

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    1/4" SCH80
    1/2" SCH80
    1/2" SCH40
    3/4" SCH80
    3/4" SCH40

  • Max. immersion length on request

    up to 10.000,00 mm (393,70'')

  • Material protection tube/ thermowell

    1.4401 (316)
    1.4749 (~446)

  • Optional coating

    Not defined

  • Process connection

    male thread:
    NPT1/2"
    NPT3/4"
    NPT1"
    compression fitting:
    flange:
    ASME 1" 150 RF (B16.5)
    ASME 1" 300 RF (B16.5)
    ASME 1" 600 RF (B16.5)
    ASME 1,5" 150 RF (B16.5)
    ASME 1,5" 300 RF (B16.5)
    ASME 1,5" 600 RF (B16.5)
    ASME 2" 300 RF (B16.5)
    ASME 2" 600 RF (B16.5)

  • Tip shape

    straight
    reduced

  • Surface roughness Ra

    1,6 μm (63,0 μin.)

  • Operating temperature range

    Type K:
    -40 °C ... 1.100 °C
    (-40 °F ...2.012 °F)
    Type J:
    -200 °C ...750 °C
    (-328 °F ...1.382 °F)

  • Max. process pressure (static)

    at 20 °C: 100 bar (1.450 psi)

  • Accuracy

    class 1 acc. to IEC 60584

  • Response time

    depending on configuration
    t50 = 3 s
    t90 = 7 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II
    IECEx
    NEPSI
    EAC Ex
    Explosion proof

  • Certification

    Gost Metrology
    SIL (transmitter only)

Documentos / Manuais / Software

Acessórios / peças sobressalentes

Nr
Order code
Specification
  • C
  • A
  • E
    • Nr E Order code TA540-

      Thermowell TA540

      Product being phased out, limited availability. Flange connection or screw in. Thermometer connection female, welded version.

    • Nr E Order code TA541-

      Thermowell TA541

      Product being phased out, limited availability. Flange connection or screw in. Thermometer connection male, welded version.

  • B
    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

  • D
    • Nr D Order code TA30H-

      Terminal Head TA30H

      Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).

  • B
    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

  • Successor

    • Produtos simples

    • Fácil de escolher, instalar e operar

    Excelência técnica

    Simplicidade

    • Produtos padrão

    • Confiável, robusto e baixa manutenção

    Excelência técnica

    Simplicidade

    • Produtos com tecnologia de ponta

    • Altamente funcional e prático

    Excelência técnica

    Simplicidade

    • Produtos especializados

    • Desenvolvidos para aplicações exigentes

    Excelência técnica

    Simplicidade

    Variável

    Versões FLEX Excelência técnica Simplicidade
    • F
    • L
    • E
    • X

    Versão Fundamental

    Atende suas necessidades básicas de medição

    Excelência técnica
    Simplicidade
    • F
    • L
    • E
    • X

    Versão Lean

    Lida com seus principais processos facilmente

    Excelência técnica
    Simplicidade
    • F
    • L
    • E
    • X

    Seleção Extended

    Otimiza seus processos com tecnologias inovadoras

    Excelência técnica
    Simplicidade
    • F
    • L
    • E
    • X

    Versão Xpert

    Controla suas aplicações mais difíceis

    Excelência técnica
    Simplicidade

    Variável