Especificações resumidas
-
Comprimento de onda do laser
Entrada: 785 nm
Modelo base: 532 nm, 785 nm, 1000 nm
Híbrido: 785 nm -
Cobertura espectral
Entrada:
300-3300 cm-1 (785 nm)
Modelo base:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Híbrido: 175-1890 cm-1 (785 nm)
Campo de aplicação
Adeptly harness the power of Raman spectroscopy with the Raman Rxn2 analyzer. Designed for use in analytical laboratories with model transfer capabilities, the Raman Rxn2 is heavily relied on for routine sample identification, support of R&D projects, early process development, and scale-up settings for in situ analysis. Available as a benchtop or on a mobile wheeled cart, the Raman Rxn2 offers location convenience and portability for process development laboratories.
Chemical: polymerization, extrusion monitoring, polymer blending, catalysis investigation
Pharmaceutical: reaction chemistry, yield crystallization, polymorph, blending, drying, granulations
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: cultured meat, fermentation, oil or fat quality
Benefícios
Reliable real-time, in situ measurements
Intuitive, embedded control software via touchscreen or remote interface
Convenience of a single base unit supporting up to four probes
-
Sequential operation for fast analysis per channel and programmable channel interrogation
Converts acquired Raman spectra into process knowledge using built-in multivariate predictors
Suitable for outputs into hazardous area/classified environments
Proven model transferability to process development and manufacturing scales
Seleção Extended
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos com tecnologia de ponta
- Altamente funcional e prático
Excelência técnica
Simplicidade
-
Produtos especializados
- Desenvolvidos para aplicações exigentes
Excelência técnica
Simplicidade
Variável
Versões FLEX | Excelência técnica | Simplicidade |
---|---|---|
Versão Fundamental Atende suas necessidades básicas de medição |
Excelência técnica
|
Simplicidade
|
Versão Lean Lida com seus principais processos facilmente |
Excelência técnica
|
Simplicidade
|
Seleção Extended Otimiza seus processos com tecnologias inovadoras |
Excelência técnica
|
Simplicidade
|
Versão Xpert Controla suas aplicações mais difíceis |
Excelência técnica
|
Simplicidade
Variável |
-
-
Informações Técnicas (TI)
Informações técnicas do Raman Rxn2
Design e especificações do sistema para o analisador
Raman Rxn2 - com tecnologia Kaiser RamanEN PT 06/08/202421/11/2023Idioma:
Português
Versão:
06/08/2024
Tamanho do arquivo:
1.2 MB
Nome do arquivo:
TI01608CPT_0323.pdf
-
-
-
Informações Técnicas (TI)
Informações técnicas do Raman Data Library
Informações e especificações do sistema para o Raman Data Library (KRDL)
EN PT 28/08/202413/08/2024Idioma:
Português
Versão:
28/08/2024
Tamanho do arquivo:
209.3 KB
Nome do arquivo:
TI01802CPT_0124.pdf
-
-
-
Instruções de Operação (BA)
Raman RunTime v6.5 Operating Instructions
Commissioning, operation, and maintenance details
for Raman RunTime v6.5 softwareEN PT 16/11/202316/11/202231/12/2020Idioma:
Inglês
Versão:
16/11/2023
Tamanho do arquivo:
6.7 MB
Nome do arquivo:
BA02180CEN_0423.pdf
-
-
-
Instruções de Operação (BA)
Raman data library User Operating Instructions
Instructions for use of Raman data library software
Idioma:
Inglês
Versão:
13/09/2024
Tamanho do arquivo:
4.4 MB
Nome do arquivo:
BA02367CEN_0124.pdf
-
-
-
Instruções de Operação (BA)
Instruções de operação para administradores do Raman Data Library
Instruções para administração do software Raman Data Library
EN PT 27/09/202411/09/2024Idioma:
Português
Versão:
27/09/2024
Tamanho do arquivo:
1 MB
Nome do arquivo:
BA02349CPT_0124.pdf
-
-
-
Instruções de Operação (BA)
Instruções de operação do Raman Rxn2
Detalhes para comissionamento, operação e manutenção
do analisador Raman Rxn2 - com tecnologia Kaiser RamanEN PT 08/07/202421/03/2024Idioma:
Português
Versão:
08/07/2024
Tamanho do arquivo:
6.7 MB
Nome do arquivo:
BA02151CPT_0524.pdf
-
-
-
Instruções curtas (KA)
Resumo das instruções de operação do Raman Data Library
Instruções resumidas e instruções de inicialização
do software Raman Data LibraryEN PT 28/08/202413/08/2024Idioma:
Português
Versão:
28/08/2024
Tamanho do arquivo:
449.5 KB
Nome do arquivo:
KA01717CPT_0124.pdf
-
-
-
Instruções curtas (KA)
Resumo das instruções de operação, Raman Rxn2
Guia de início rápido para o analisador
Raman Rxn2 - com tecnologia Kaiser RamanEN PT 26/07/202421/11/2023Idioma:
Português
Versão:
26/07/2024
Tamanho do arquivo:
2.2 MB
Nome do arquivo:
KA01544CPT_0323.pdf
-
-
-
Instruções de Segurança Ex (XA)
Instruções de segurança do Raman Rxn2
Certificações de áreas classificadas e instruções de instalação
para o analisador Raman Rxn2 alimentado pela tecnologia Kaiser RamanEN PT 06/08/202407/12/2023Idioma:
Português
Versão:
06/08/2024
Tamanho do arquivo:
1.1 MB
Nome do arquivo:
XA02700CPT_0323.pdf
-
-
-
PU (publicação)
Endress+Hauser - your one-source Life Sciences technology partner
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).Idioma:
Inglês
Versão:
27/06/2024
Tamanho do arquivo:
1.9 MB
Nome do arquivo:
PU01585CEN_0124.pdf
-
-
-
PU (publicação)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Idioma:
Inglês
Versão:
19/04/2022
Tamanho do arquivo:
1.1 MB
Nome do arquivo:
PU01447CEN_0222.pdf
-
-
-
PU (publicação)
Prioritize scalability for an efficient biopharmaceutical product development lifecycle
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).Idioma:
Tcheco
Versão:
06/09/2024
Tamanho do arquivo:
381.4 KB
Nome do arquivo:
PU01584CEN_0124_cz_view.pdf
-
-
-
PU (publicação)
Endress+Hauser - ライフサイエンス技術のワンストップパートナー
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。Idioma:
Japonês
Versão:
04/10/2024
Tamanho do arquivo:
2.7 MB
Nome do arquivo:
PU01585CJA_0124_Graphic_EH biopharma trust.pdf
-
-
-
PU (publicação)
Advanced process and product control in fermentations - Raman spectroscopy for composition analysis in a lab or process
An overview of Raman spectroscopy analyzer systems (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45
probe), powered by Kaiser Raman technology, for fermentation
compositional analysis in a lab or process applicable to biotechnology
in the food & beverage industry.Idioma:
Inglês
Versão:
03/03/2022
Tamanho do arquivo:
603 KB
Nome do arquivo:
PU01457CEN_0122.pdf
-
-
-
PU (publicação)
Kaiser Raman technology and Sartorius BioPAT Spectro® collaboration Q&A - Scalable, real-time bioprocess monitoring solutions
A Q&A about how our Raman spectroscopy analyzer systems
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
and Rxn-46 probe), powered by Kaiser Raman technology, integrates
with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for
high throughput and single use (SUB) bioprocessingin the
biopharmaceutical life science industry.Idioma:
Inglês
Versão:
08/12/2021
Tamanho do arquivo:
943.7 KB
Nome do arquivo:
PU01446CEN_0121.pdf
-
-
-
PU (publicação)
Raman data library -- Faster time to market with increased insight, productivity, and data integrity
This document provides insight into the core and cGxP
features of Raman data library (data organization, visualization,
user management, and univariate analysis for Raman Rxn2
and Raman Rxn4 analyzers), while also addressing common
questions regarding the software's functionalities.Idioma:
Inglês
Versão:
21/06/2024
Tamanho do arquivo:
3.3 MB
Nome do arquivo:
PU01583CEN_0124.pdf
-
-
-
PU (publicação)
ライフサイエンス産業向けのラマンアプリケーションガイド -ライフサイエンスのための信頼できる組成分析
ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。Idioma:
Japonês
Versão:
02/08/2024
Tamanho do arquivo:
1.4 MB
Nome do arquivo:
PU01447CJA_0222_Raman_App_Guide_for_LifeScience.pdf
-
-
-
PU (publicação)
Prioritize scalability for an efficient biopharmaceutical product development lifecycle
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).Idioma:
Inglês
Versão:
27/06/2024
Tamanho do arquivo:
753.7 KB
Nome do arquivo:
PU01584CEN_0124.pdf
-
-
-
PU (publicação)
発酵における高度なプロセスと 製品の制御 -ラボまたはプロセスにおける 組成分析用のラマン分光法
食品・飲料産業のバイオテクノロジーに適用されるラボやプロセス
での発酵組成分析のための、Kaiserラマンテクノロジーを搭載した
ラマン分光アナライザーシステム(ラマンRxn2アナライザー、ラマ
ンRxn4アナライザー、Rxn-10プローブ、Rxn-45プローブを含む)の
概要。Idioma:
Japonês
Versão:
02/08/2024
Tamanho do arquivo:
1.4 MB
Nome do arquivo:
PU01457CJA_0122_Adv_Process_Product_Control_Fermentations.pdf
-
-
-
PU (publicação)
Raman calibration and verification kits - Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).Idioma:
Inglês
Versão:
13/12/2023
Tamanho do arquivo:
2.1 MB
Nome do arquivo:
PU01518CEN_0223.pdf
-