©Endress+Hauser
Characteristic / Application
S.A. Style universal range of application usable with or without a thermowell
Thermowell / protection tube
to use with or without thermowell (can be ordered separately)
Insert / probe
mineral insulated (MI), flexible
Max. immersion length on request
up to 90.000 mm (3.543,31'')
Material protection tube/ thermowell
1.4401 (316) 1.4841 (310) Alloy 600 (2.4816)
Process connection
Adjustable compression fitting: NPT 1/8" NPT 1/4" NPT 3/8" NPT 1/2" G1/2"
Operating temperature range
Type J: -210 ...760 °C (-346 ...1.400 °F) Type K: -270 ...1.100 °C (-454 ...2.012 °F) Type N: -270 ...1.100 °C (-454 ...2.012 °F) Type T: -270 ...400 °C (-454 ...725 °F)
Max. process pressure (static)
at 20 °C: 10 bar (150 psi) without thermowell
Accuracy
class 1 acc. to IEC 60584
Response time
depending on configuration
Integration head transmitter
Certification
EN10204 3.1 Material traceability
1 documents
Technical Information
TLSC2 thermocouple sensor, South African style
Fixed insert, adjustable compression fitting Assembly with flexible tails and quick disconnect plugs and jacks
EN
08/07/2014
23/11/2012
21/06/2011
Language:
English
Version:
08/07/2014
File size:
310.2 KB
File name:
TI00156ren_0314.pdf