Specs at a glance
-
Accuracy
(Pt100, -50...200 °C) <= 0,15 K
(Pt100, -58...392 °F) <= 0,15 K
Field of application
The iTEMP TMT36 is a reliable, long lasting, single-channel IO-Link temperature head transmitter with a form B connection head. Individual transmitter-sensor matching with Callendar van Dusen linearization further improves the temperature measurement accuracy of RTD sensors. The IO-Link capable iTEMP TMT36 can be installed in all modular Endress+Hauser thermometers to digitize a larger number of applications with special requirements using IO-Link technology.
The temperature transmitter is characterized by its reliability, long-term stability, high precision and diagnostic functions
For maximum safety and availability
Installation in terminal head form B (flat face), or on DIN rail with DIN rail clip
IO-Link (1x PNP, NPN or push-pull switch output, configurable)
Benefits
Push-in terminals for fast, tool-free wiring during installation or maintenance
Simple parametrization via free software tools (requires SFP20)
Transmitter-sensor matching using Callendar van Dusen linearization for critical measurement points
Improved RTD measurement accuracy up to 0.15 K and long-term stability
Safe and reliable operation
IO-Link technology to digitize the the last mile of your plant
Videos
Fundamental selection
-
Simple products
- Easy to select, install and operate
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Head transmitter
-
Input
1 x RTD
-
Output
1 x IO-Link
-
Auxiliary power supply
18...30 V DC
-
Communication
IO-Link
-
Installation
Terminal head form B
-
Accuracy
(Pt100, -50...200 °C) <= 0,15 K
(Pt100, -58...392 °F) <= 0,15 K -
Galvanic isolation
no
-
Certification
CSA General Purpose
-
-
Technical Information (TI)
TI iTEMP TMT36
-
Technical Information (TI)
English version - 10/2023Temperature transmitter
EN 10/10/2023Language:
English
Version:
10/10/2023
File size:
794.4 KB
File name:
TI01717TEN_0123-00.pdf
-
-
-
Operating Instruction (BA)
BA iTEMP TMT36
-
Operating Instruction (BA)
English version - 10/2023IO-Link temperature transmitter
EN 10/10/2023Language:
English
Version:
10/10/2023
File size:
1.3 MB
File name:
BA02289TEN_0123-00.pdf
-
-
-
Short Instruction (KA)
KA iTEMP TMT36
-
Short Instruction (KA)
English version - 10/2023IO-Link temperature transmitter
EN 10/10/2023Language:
English
Version:
10/10/2023
File size:
414 KB
File name:
KA01645TEN_0123-00.pdf
-
-
-
Installation Instructions (EA)
Bild Temperaturtransmitter TMT36
-
Installation Instructions (EA)
English version - 01/2024Bild Temperaturtransmitter TMT36
EN 01/01/2024Language:
English
Version:
01/01/2024
File size:
127.1 KB
File name:
Bild TMT36.pdf
-
-
-
Special Documentation (SD)
SD Endress+Hauser IO-Link devices
-
Special Documentation (SD)
English version - 12/2024Endress+Hauser IO-Link function blocks
For Siemens TIA PortalEN 01/12/2024Language:
English
Version:
01/12/2024
File size:
4.2 MB
File name:
SD03368SEN_0124-00.pdf
-
-
-
Special Documentation (SD)
SD Endress+Hauser IO-Link devices
-
Special Documentation (SD)
English version - 03/2025Endress+Hauser IO-Link Add-On Instructions
for Rockwell Automation Studio 5000®EN 01/03/2025Language:
English
Version:
01/03/2025
File size:
6.7 MB
File name:
SD03386SEN_0125-00.pdf
-
-
-
Innovation (IN)
La forma perfetta per il tuo punto di misura
-
Innovation (IN)
Italian version - 10/2024La forma perfetta per il tuo punto di misura
Trasmettitori di temperatura Endress+HauserLanguage:
Italian
Version:
30/10/2024
File size:
7.2 MB
File name:
IN01338T_IT.pdf
-
-
-
Innovation (IN)
The perfect fit for your measuring point
-
Innovation (IN)
English version - 07/2024The perfect fit for your measuring point
Temperature transmitters from Endress+HauserLanguage:
English
Version:
31/07/2024
File size:
1.5 MB
File name:
IN01338T_09EN.pdf
-
-
-
Innovation (IN)
eBrochure iTEMP TMT36
-
Innovation (IN)
English version - 02/2024eBrochure iTEMP TMT36
Language:
English
Version:
20/02/2024
File size:
1000.1 KB
File name:
IN01314T_09 TMT36.pdf
-
-
-
Innovation (IN)
eBrochure iTEMP TMT36
-
Innovation (IN)
Czech version - 09/2024eBrochure iTEMP TMT36
Language:
Czech
Version:
25/09/2024
File size:
2 MB
File name:
FO_iTEMP_eBrochure_TMT36_IN01314T_09-en-cs_cz-C.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .