Proline Prosonic Flow 91W
Ultrasonic flowmeter
Device with automatic frequency scan for max. measuring performance and cost-effective transmitter
The Prosonic Flow W clamp-on sensor is specially designed for water and wastewater applications. Combined with the cost-effective Prosonic Flow 91 transmitter with push buttons, Prosonic Flow 91W is ideally suited for flow monitoring in the water industry.
-
Benefits
Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 4000)
Long-term stable signal - maintenance-free permanent mounting from outside with coupling pads
Process transparency – diagnostic capability
Economical transmitter –...
-
Field of application
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Clamp-on flow measurement of process water, salt water, deminerialized water, drinking & wastewater.
Device properties:
Medium temperature: –20 to +80...
Documents / Manuals / Software
-
Prosonic Flow
90U, 90W, 91W, 93C, 93U, 93W
Technical
Information (SI units)
Ultrasonic Flow Measuring System
Volume Flow Measurement for Standard Applications with Water, Wastewater
and Process WaterTechnical Information (TI) -
Proline Prosonic 91W
Technical Information
Ultrasonic Flow Measuring System
Flowrate measurement for standard applications with
drinking water and process water.Technical Information (TI) -
Prosonic Flow 91
Operating Instructions
Ultrasonic Flow Measuring System
Flow rate measuring for
standard applications with
drinking water, wastewater and
process water
(incl. Description of Device Functions)Operating Instruction (BA) -
Proline Prosonic Flow 90, 91, 93
Sonderdokumentation / Special
Documentation
Montageanleitung für die Verbindung Sensoren / Messumformer bei
Verwendung von flexiblen Kabelschutzrohren
Mounting instruc
tions for the sensor / transmitter connection using flxible conduitShort Instruction (KA)11/06German , English -
Proline Prosonic Flow 91W
Brief Operating Instructions
Ultrasonic flow measuring system
Short Instruction (KA)02/12English -
Permanent Coupling Pads
Installation Instructions
Prosonic Flow 91W, 93W, P
Mounting Instruction (EA) -
Replacing T-DAT
Installation Instructions
Promag 23, 53, 55, Promass 83, 84, 8WF, 8ME, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 91, 93, t-mass 65Mounting Instruction (EA) -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Mounting Instruction (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Mounting Instruction (EA) -
Replacing transmitter parts
Installation Instructions
Promag 10, Prosonic Flow 91 W
Mounting Instruction (EA) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Prosonic Flow 91
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 91 HART: 1.00.02Manufacturer Information (MI) -
Proline Prosonic Flow 91
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 91 HART: 1.00.03Manufacturer Information (MI) -
Proline Prosonic Flow 91
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 91 HART: 1.02.00Manufacturer Information (MI) -
Proline Prosonic Flow 91
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 91 HART: 1.01.00Manufacturer Information (MI) -
Leckagen auf der Spur
In Trinkwasserversorgungsnetzen kommt es immer wieder zu
Wasserverlusten. Kleine Leckagen mit schleichenden Verlusten
lassen sichnur schwer aufspüren. Bei der Detektivarbeit bietet
das moderne Ultraschall-Durchflussmessgerät Prosonic Flow 91W von
Endress+Hauser entscheidende Vorteile.Publications (PU)08/13German -
Pomiary przepływu zapewniają integralność instalacji
rurociągowej_APA_05_2011
W artykule przedstawiono zastosowanie w procesach przemysłowych
nowoczesnej i nieinwazyjnej ultradźwiękowej technologii pomiaru
przepływu, która oparta jest na pomiarach czasu przejścia fali
ultradźwiękowej.Publications (PU)04/12Polish -
Pomiary przepływu apa_05_2011
Zastosowanie w procesach przemysłowych nowoczesnej
i nieinwazyjnej ultradźwiękowej technologii pomiaru przepływu, która
oparta jest na pomiarach czasu przejścia fali ultradźwiękowej.Publications (PU)03/12Polish -
Flow measurement in utilities - for the US Market
Energy management in your hands - customized solutions for
compressed air, gas, steam and waterCompetence Brochure (CP)12/10English -
Flow measurement from outside the pipe: Cost-effective – flexible –
robust
Ultrasonic clamp-on technology
Competence brochureCompetence Brochure (CP)05/10English -
Ultraschall-Durchflussmessung von außen: Kostengünstig – flexibel –
robust
Clamp-on-Messtechnologie
KompetenzbroschüreCompetence Brochure (CP)05/10German -
Water supply for the beverage industry (beer production)
200 Prosonic Flow 91W meters measure the water intake
Case Studies (CS)11/12English -
Water for irrigation (clamp-on ultrasonic flow measurement)
Transforming 100000 hectares of arid land into fertile agricultural land
with the potential to support around 20 000 farmersCase Studies (CS)07/12English -
Cost transparency through energy monitoring
Data collection and visualization of the energy consumption.
Case Studies (CS)01/13English -
Prosonic Flow 91W / 93W / 93P
Jetzt mit “Koppelpad” für die sichere Schallübertragung und höchste
Performance bei der Clamp-on-DurchflussmessungInnovations (IN)07/19German -
Prosonic Flow 91W / 93W / 93P
Now with a “coupling pad” for reliable sound transmission and maximum
performance during clamp-on flow measurementInnovations (IN)07/19English -
Prosonic Flow 91W / 93W / 93P
Maintenant avec un "patin de couplage" pour une transmission fiable du
son et des
performances maximales lors de la mesure de débit clamp-onInnovations (IN)07/19fr -
Prosonic Flow 91W
Ultrasonic clamp-on flow measuring system for non-contact flow
measurement of steel tubing and plastic pipes without interrupting o
peration.Tender Text09/06us -
Prosonic Flow 91W
Ultraschall Clamp-on Durchflussmesseinrichtung zur berührungslosen
Durchflussmessung auf Stahlrohr- und Kunststoffleitungen ohne Be
triebsunterbrechung.Tender Text02/09German -
EDD Single, PDM_HART_FL_ProsonicFlow91_0x0062_0x01_0x01, 13.11.2018 (Flow, Prosonic Flow, 0x0062)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow91_0x0062_0x02_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0062)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow91_0x0062_0x03_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0062)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicFlow_91_HART_FW1_02_zz_Dev_Rev_3, 06.07.2019 (Flow, Prosonic Flow, 0x0062)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_91_V1_01_xx, 06.07.2019 (Flow, Prosonic Flow, 0x0062)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_91_V1_00_xx, 06.07.2019 (Flow, Prosonic Flow, 0x0062)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Prosonic Flow Clamp on
Installation Video
This video will guide you through the basic steps of programming and
installing the Prosonic Flow clamp-on flowmeter.Animation11/07English -
Prosonic Flow 91
Product Code: 91W-
Declaration Number: EC_00298_01.16EU DeclarationGerman , English , fr -
Prosonic Flow 91, Prosonic Flow 93
Product Code: 91W-, 93C-, 93P-, 93W-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TС RU C-D.CH.AL32.B.05672MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP004 003 127MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 93
Product Code: 91W-, 93C-, 93P-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP004 003 127MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Prosonic Flow 91
Product Code: 91W-
Region/Country: USA
Approval Agency: FM
Category: I/2/A,B,C,D/
Protection: DIP, NIExplosion ProtectionEnglish -
Prosonic Flow 91
Product Code: 91W-
Region/Country: Canada
Approval Agency: CSA
Category: I/2/A,B,C,D/, II/1/E,F,G/Explosion ProtectionEnglish -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93W-
Region/Country: Russia (GOST)
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 48356_1MetrologyRussian -
Prosonic Flow 91, Prosonic Flow B
Product Code: 91W-, 9B2B-
Region/Country:
Approval Agency: MSST
Approval Number: MSST_2247MetrologyRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93T-, 93W-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A_48356MetrologyEnglish , Russian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Approval Agency: RM RSMarineRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 93P-, 93C-, 93W-, 91W-, 92F-, 93TA1-
Region/Country: International
Approval Agency: RM RSMarineRussian
Accessories / Spare parts
-
-
Nr A Order code 71138304
Kit Main-PCB 91W 85-250VAC
-
Nr A Order code 71138309
Kit Main-PCB 91W 20-28VAC 11-40VDC
-
-
-
Nr 3 Order code 50104749
Kit 10 fuses 1.0 A/250 slow
-
Nr 3 Order code 50104750
Kit 10 fuses 1.6 A/250 slow
-
-
-
Nr B Order code 50104745
Kit display 10/91W with keyboard
-
-
-
Nr 2 Order code 50094004
Kit T-DAT Transmitter Data Chip
-
-
-
Nr 8 Order code 50097147
-
-
-
Nr 1 Order code 50108138
Kit Terminal Block 10/1YH/91W
-
-
-
Nr 5 Order code 50104746
Kit cover 10/91W with window
-
-
-
Nr 6 Order code 50104747
Kit cover 10/1YH/91W blind version
-
-
-
Nr 9 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 9 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 9 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
-
-
Nr 4 Order code 50104748
Kit PCB/Display carrier 10/91W
-
-
-
Nr 11 Order code 71022832
Kit cable glands Wall holding 91W
-
-
-
Nr 10 Order code 71022835
Kit Wall holding Prosonic 91W cpl.
-
-
-
Nr 7 Order code 71023273
Kit housing gasket 91W field housing
-
-
-
Order code
Overview auxiliary equipment see spare part picture
-
Order code DK9WS-
-
Order code DK9SS-
Prosonic Flow 91/93/93T,sensor cable set
-
Order code DK9SH-
Prosonic Flow W/P, sensor holder set
-
Order code DK9IC-
Prosonic Flow W/P, install.set Clamp On
Only use with Prosonic Flow 91 and 93 transmitter.
-
Order code DK9CB-
Prosonic Flow 91/93 W/P, conduit adapter
-
Order code DK9WM-
Transmitter 91/90/93, Mounting set
-
Order code DK9CM-
-
-
Predecessor