Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Level measurement, capacitive. Application: liquids. Partly insulated rod probe. Suitable for small vessels. Additional safety feature. :: High pressure / high temperature :: Longtime stable tightness
Partly insulated rod probe, suitable for storage and buffer tanks T: Standard application A: North America Certificate (IS,XP) S: Additional safety feature
Specialities
Foam detection
Supply / Communication
3-wire PFM
Ambient temperature
Standard: -40 °F ... 160 °F With separate housing: -80 °F ... 250 °F
Process temperature
-60 °F ... 390 °F
Process pressure / max. overpressure limit
Vacuum ... 360 psi
Main wetted parts
Insulation material: PTFE 316L
Process connection
G 3/4A, G 1A /NPT 3/4", NPT 1" Flange from DN25.../ASME 1".../JIS...
Process connection hygienic
Tri-Clamp ISO2852 Dairy coupling
Sensor length
Total length of probe 3 m Inactive length: max. 1,5m
Communication
3-wire PFM
Certificates / Approvals
FM CSA
Options
Separate housing (HTC), Inactive length, Build-up compensation